15
Signal settings/Output
3) To load a new NIT le click on the option LOAD NEW FILE in the lower part of the
screen. A new window lets you select the location and the name of the NIT le that you
wish to load.
NOTE
The model NIT option lets you combine the NIT information of the unit with an
external NIT, resulting in a combined NIT of both sets of information. If the TSIDs
coincide, they are replaced by those of the unit.
Output
1) Select the SETTINGS menu and then the OUT-
PUT submenu.
The RF OUTPUT tab displays the conguration
parameters of the output signal radio frequency and
lets you modify it for exible setting in the output of
the unit.
J
PARAMETERS:
F
FREQUENCY: displays the output frequen-
cy of the current radio frequency carrier and
allows you to modify its value (directly on the
value eld or increasing or decreasing unit
by unit using the buttons to the left of the
eld). The frequency value must be within
the valid range for the VHF or UHF bands.
F
OFDM MODE: congures the OFDM mode by selecting from the values 2K and
8K.
F
BANDWIDTH: congures the bandwidth by selecting from the values 6, 7 and 8
MHz.
F
GUARD INTERVAL: congures the guard interval by selecting from the values 1/4,
1/8, 1/16 and 1/32 of symbol.
F
CONSTELLATION: congures the constellation of the output modulation by se-
lecting from the options 16QAM and 64QAM.
F
CODE RATE: congures the redundant code rate by selecting from the values 1/2,
2/3, 3/4, 5/6 and 7/8.
F
ATTENUATION: congures the attenuation for the radio frequency carrier signal
to the output using a sliding bar to vary this value within the range of 0dB to 47 dB.
F
MAX BIT RATE: reports the maximum binary data speed in the output of the unit.
F
NULL PERCENTAGE: reports on the percentage of binary data in the output
without information.
F
MINIMUM C/N (THEORETICAL): reports the minimum theoretical carrier to
noise ratio in the output.
F
TEMPERATURE: displays the operating temperature in the unit.
EN
Komentáře k této Příručce